Skip to content
Logo
  • English
    • German

Alpha direct Balance base station

  • Device overview
  • Intended use
  • Electric connection
  • Automatic hydraulic balancing
  • Commissioning mode
  • Montage
  • Maintenance
  • Dismantling

Alpha direct Balance Switch NFC base station

  • Device overview
  • Register description
  • Automatic hydraulic balancing
  • Electric connection
  • Maintenance
  • Dismantling
  • LED signaling

Alpha direct Balance Downloads

  • Alpha direct Balance Downloads
  • Alpha direct Balance Downloads
  • Alpha direct Balance Switch Downloads
  • Certificates
  • Data sheets

Alpha direct Balance FAQs

  • Is the OEM Alpha direct Balance System compatible with other thermostat components with their own controls?
  • Can any thermostats be used with the base station?
  • Does the OEM Alpha direct base station need to be calibrated?
  • Is the base station capable of cooling?
  • Do circuit control valves or other balancing devices need to be fitted to the distribution network?
  • Can a boiler be controlled?
  • Can the OEM Alpha direct Balance open the thermostat valve periodically during the summer to stop it from getting stuck?
  • Are flow indicators still required for the OEM Alpha direct Balance System?
View Categories
  • Systemauswahl
  • Alpha direct Balance Switch
  • Alpha direct Balance Switch NFC base station
  • Device overview

Device overview

Connections and indications #

1 – Boiler connection
2 – Pump connection
3 – Protective earth connection (230 V only)
4 – Voltage supply
5 – Fuse
6 – Temperature limiter or dew point monitor
7 – Changeover heating/cooling
8 – Setback temperature channel external timer
9 – Thermostat connection
10 – LED
11 – NFC antenna
12 – Connection of valve drives
13 – Strain relief

Technical data #

Operating voltage24 V ±20 %, 50 Hz,
230 V ±10 %, 50 Hz
Power consumptionmax. 50 VA
Power consumption (idle)<1 W
Fuse24 V: T2A
230 V: T4AH
Connectable room controllersmax. 8
Connectable room controllersA 20×05, AST 20×05, A 40×05, AST 40×05
Connectable valve drivesmax. 12 actuators
Inrush current per valve drive230 V: max. 500 mA
max. permissible nominal load of the connectable valve drives24 V: max. 24 W
Pump connection Switching capacity2 A, 200 VA induktiv
– Turn-on delayparametrisable (default: 2 minutes)
– Follow-up timeparametrisable (default: 2 minutes)
Boiler connection Switching capacity2 A, 200 VA induktiv
– Turn-on delayparametrisable (default: 0 parametrisable )
– Follow-up timeparametrisable (default: 0 parametrisable )
Pump protectionparametrisable (default: 3 days / 5 min.)
Valve protectionparametrisable (default: 3 days / 5 min.)
Valve drive operating principleNC
Ambient temperature0 … 50 °C
Storage temperature / transport temperature-20 … +70 °C
Ambient humidity5-80 %, non-condensing
ERP class according to EU 811/20131=1 %
Contamination degree2
Rated impulse voltage1500 V
Protection class24 V: III
230V: II
Protection type:IP20
FunctionType 1 / type 1.C
Dimensions (H x W x D)90 x 326,5 x 52 mm

Display #

LED heating zonesgreen (one LED per HZ)
LED fusered
LED powergreen / red (two-coloured)
LED pumpgreen
LED boilergreen
LED heating / coolinggreen
LED ModbusFlashing orange for Modbus activity
Updated on August 15, 2025
Register description
Table of Contents
  • Connections and indications
  • Technical data
  • Display

© 2024 | 300724

  • Supportrequest
  • Privacy Statement
  • Imprint
  • Supportrequest
  • Privacy Statement
  • Imprint