CAR / CAF / CAE (calibration)

  • adjustment range: -10 K … +10 K
  • Default: 0 K

CAR: Setpoint balancing of internal temperature sensor

Prerequisite for use:

  • Internal sensor A or AF set in sensor mode (→ SMO)

CAF: Setpoint balancing for floor sensor

Prerequisite for use:

  • Floor sensor F, AF or A2F set in sensor mode (→ SMO)

CAE: Setpoint balancing for external sensors

Prerequisite for use:

  • Sensor A2 or A2F set to sensor mode (→ SMO)