Skip to content
Logo
  • English
    • German

Alpha Smart system

  • Alpha smart system
  • Alpha smartware

Alpha Smart stand-alone system

  • Standalone principle
  • Pairing
  • Upgrade standalone solution
  • Pairing base – room operating unit

Alpha Smart app

  • General Terms of Use for the Alpha Smart App
  • Privacy Policy
  • Installer mode
  • Location
  • Features
  • Download
  • System requirements
  • Creating a user account
  • Deleting a user account
  • Login with multiple smartphones
  • Claiming
  • Add device
  • Delete device from the app
  • Scan QR code
  • Terms and conditions, privacy policy
  • Location transfer

Alpha Smart IoT gateway

  • Feature
  • Data security
  • Gateways per app
  • Gateways per location
  • Data duplication
  • IP ports

Alpha Smart cloud

  • Features
  • Data center location
  • Data security
  • Update (OTAU)

Radio protocol cSP-L

  • Wireless protocol
  • Encryption
  • Frequencies
  • Duty Cycle
  • Wireless range
  • Max. number of devices
  • Wireless communication

Alpha Smart system radiant heating system

  • Connection set
  • Auto / Manu mode
  • Floor sensor
  • Components
  • Automatic hydraulic balancing
  • Switching time
  • How many switching times can I store in the app?
  • Smart start/stop
  • Holiday mode
  • Radiant heating system

Alpha Smart system downloads

  • Alpha Smartware room control devices Downloads
  • Alpha Smartware IoT Gateway Downloads
  • Alpha Smartware Base Station – Downloads
View Categories
  • Systemauswahl
  • Alpha Smartware
  • AD_Automatisierter hydraulischer Abgleich
  • A practical guide for technicians: Hydraulic balancing using automated systems

A practical guide for technicians: Hydraulic balancing using automated systems

Practical guidance for technical staff on carrying out hydraulic balancing with the aid of individual room control systems featuring automated hydraulic balancing

Base stations with integrated control systems for automated hydraulic balancing do not entirely replace the process of hydraulic balancing in accordance with Method B, nor do they exempt users from complying with the fundamental requirements for hydraulic balancing under Method B. The base stations cannot influence sections of the pipework network located upstream of the heating manifold. They only start to affect the system from the heating manifold onwards.

The base stations handle the automated balancing and demand-based distribution at heating circuit level. However, they do not replace either the heating load as a basis for planning, or the settings for the heat generator, the heating curve, the pump system or the technical documentation.
In practice, this means: At the heating circuit level, the amount of manual adjustment required is significantly reduced. However, the technician’s overall responsibility for the system remains unrestricted.

The following section sets out in detail, in accordance with the checklist issued by the Federal Ministry for Economic Affairs and Climate Action (BMWK) and the German Federal Office for Economic Affairs and Export Control (BAFA), which elements of hydraulic balancing in accordance with Method B are replaced by the base station and which are to be carried out by the installation contractor.

All key steps in hydraulic balancing are assessed in accordance with the following criteria and serve as a basis for action for heating engineers in practice.

StepDescribes the relevant practical stage of hydraulic balancing.
Job description: TechnicianIncludes all activities that remain the responsibility of the specialist company.
Takeover by the base stationIndicates functions that are carried out automatically or supported by the base station.
Not applicableIndicates only those manual steps that are no longer required.