Skip to content
Logo
  • English
    • German

Alpha smart system

  • Alpha smart system
  • Alpha smartware

Alpha smart stand-alone system

  • Standalone principle
  • Pairing
  • Upgrade standalone solution
  • Pairing base – room operating unit

Alpha smart app

  • General Terms of Use for the Alpha Smart App
  • Privacy Policy
  • Installer mode
  • Location
  • Features
  • Download
  • System requirements
  • Creating a user account
  • Deleting a user account
  • Login with multiple smartphones
  • Claiming
  • Add device
  • Delete device from the app
  • Scan QR code
  • Terms and conditions, privacy policy
  • Location transfer

Alpha smart IoT gateway

  • Feature
  • Data security
  • Gateways per app
  • Gateways per location
  • Data duplication
  • IP ports

Alpha smart cloud

  • Features
  • Data center location
  • Data security
  • Update (OTAU)

Radio protocol cSP-L

  • Wireless protocol
  • Encryption
  • Frequencies
  • Duty Cycle
  • Wireless range
  • Max. number of devices
  • Wireless communication

Alpha smart system radiant heating system

  • Connection set
  • Auto / Manu mode
  • Floor sensor
  • Components
  • Automatic hydraulic balancing
  • Switching time
  • How many switching times can I store in the app?
  • Smart start/stop
  • Holiday mode
  • Radiant heating system

Alpha Smart System Downloads

  • Alpha Smartware room control devices Downloads
  • Alpha Smartware IoT Gateway Downloads
  • Alpha Smartware Base Station – Downloads
View Categories
  • Systamauswahl
  • Systemauswahl
  • Alpha smartware
  • Alpha smart system radiant heating system
  • Floor sensor

Floor sensor

If the connection set is configured as a floor sensor, the following values can be set:

Adjustable valueTemperature [°C]
1,018,0
1,218,4
1,418,8
1,619,2
1,819,6
2,020,0
2,220,4
2,420,8
2,621,2
2,821,6
3,022,0
3,222,4
3,422,8
3,623,2
3,823,6
4,024,0
4,224,4
4,424,8
4,625,2
4,825,6
5,026,0
5,226,4
5,426,8
5,627,2
5,827,6
6,028,0
7,030,0
7,230,4
7,430,8
7,631,2
7,831,6
8,032,0
8,232,4
8,432,8
8,633,2
8,833,6
9,034,0
9,234,4
9,434,8
9,635,2
9,835,6
10,036,0
10,236,4
10,436,8
10,637,2
10,837,6
11,038,0
11,238,4
11,438,8
11,639,2
11,839,6
12,040,0

Note:
Depending on the actual position of the external sensor in the screed, the surface temperature may deviate from the set floor temperatures.

→ see user information Connection set with external sensor for Alpha Smartware room operating unit (AT 61201-N)