Skip to content
Logo
  • English
    • German

Motoric Valve Drive 24 V (AM3)

  • Disassembly
  • Antitheft device
  • Technical data
  • Diagrams
  • Feedback
  • Function display
  • Initialization
  • Presets
  • Connection
  • Mxx 468×6
  • App
  • Manual setting
  • Notes
  • Montage
  • App
  • App functions
  • Error codes
  • Dimensions

Motoric Valve Drive 6: 24 V proportional failsafe

  • App
  • Disassembly
  • Antitheft device
  • Manual setting
  • App
  • Notes
  • MxxF 468×6
  • Montage
  • Connection
  • Initialization
  • Function display
  • Feedback
  • Diagrams
  • Technical data
  • Antitheft device
  • Dismantling
  • App
  • Error codes
  • Dimensions
  • Presets
  • App functions
  • Failsafe function

Motoric Valve Drive 6: 24 V modbus

  • Function display
  • App
  • Connection
  • Technical data
  • Error codes
  • Diagrams
  • Initialization
  • Presetting
  • App functions
  • MPM 468×6
  • Disassembly
  • Antitheft device
  • Manual setting
  • Dimensions
  • Montage
  • App
  • Notes
  • App

Motoric Valve Drive 6 Downloads

  • Installation instructions
  • Data sheets
  • Motoric Valve Drive 6: 24 V modbus Downloads
  • Motoric Valve Drive 6: 24 V proportional, proportional failsafe Downloads
  • Motoric Valve Drive 6 Downloads
View Categories
  • Systamauswahl
  • Systemauswahl
  • Motoric Valve Drive 6
  • Motoric Valve Drive 24 V (AM3)
  • App functions

App functions

FUNCTIONDESCRIPTIONDISPLAY
DEVICE OPERATIONS
Read
Read from deviceReading out the settings of the
OEM Motoric Valve Drive 6: 24 V Proportional
– Ready to scan:
Hold your smartphone near to NFC tag

– Display:
Data was read successfully
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.
Read from filePrerequisite for use:
File stored on the mobile device.

– Reading the settings from a file stored on the mobile device

Ways to store a file on the mobile device:
– Sending files as attachments by message or e-mail
– Storage of file by Write to file command
Display of the file management of the mobile device
Write
Write to deviceSettings are written to the OEM Motoric Valve Drive 6: 24 V Proportional– Ready to scan:
Hold your smartphone near to NFC tag

– Display:
Data was read successfully
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.
Write to fileScanned settings are stored as a file in the memory of the mobile device.
The file can be used for
– the dispatch by message or mail
– the setup of further OEM Motoric Valve Drive 6: 24 V Proportional devices
Display of the file management of the mobile device
Verify
Verify deviceComparison of the settings displayed in the Settings menu and the settings in the OEM Motoric Valve Drive 6: 24 V Proportional– Ready to scan:
Hold your smartphone near to NFC tag

– Display:
Data was read successfully
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.

Result:
Validation successful: identical settings
or
Verification failed: different settings
Active operations
Start initializationInitialization of the OEM Motoric Valve Drive 6: 24 V Proportional

The actuator travels along the actuator path and valve path. The opening and closing points of the valve are stored.
Your device will now begin with the initialization process.
Go to positionSetting the actuator positionSequence:
1. Go to position
2. Confirm
3. Ready to scan:
Hold your smartphone near to the NFC tag.
4. your device will now go to the specified position
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.
Factory resetAdjusts the parameters of the OEM Motor-ic Valve Drive 6: 24 V Proportional to the delivery state.Sequence:
1. Warning message
2. Scan process
Settings
ForceSetting the force in the levels:
100 N, 125 N, 150 N, 200 N
Runtime15 s/mm, 30 s/mm
Valve path recognition (VPR)ON | OFF
Display illuminationON | OFFTurns the LCD backlight on or off.
Drive path2 – 8.5 mmLimitation of the actuator path when the VPR is switched off. Use as a “limiter”.
Bypass0 … 50 %Limitation of the actuator travel in the other direction.

Application: Ensure minimum flow to protect against frost.

Note: Both the rubber diaphragm in the valve and the backlash in the adapter and the gear unit can influence the position. Please check the position!
Valve positionmm | %Sets the preferred display on the LC display.
Failsafe position0 %0 … 100 %,
steps of 10 % (only for MPxF)
Valve Curve
Valve curve
LinearLinear | EQP
Feedback range
Functionality
1 – 9 V1 – 9 V | 1 – 5 V | 0 – 10 V
Control voltage – start
Control voltage – start
0.5 V0 V … 10 V
(steps of 0.1 V)
Control voltage end
Control voltage – end
10 V0 V … 10 V
(steps of 0.1 V)
Device Operations
ModeMPxMPx | M3x

.NOTE.
All modifications must only be carried out with the appropriate expertise. Incorrect settings can lead to malfunctions of the drive, a malfunction of the control system and consequential costs. The manufacturer does not accept any responsibility for incorrect settings and their consequences.
Changes are accepted after the actuator is switched on again.

Adjustable modes

FunctionValve pathDescription
MPRProportionalpreset, fixed– Valve path recognition switched off, path fixed
MPVProportionalValve path recognition– 3-pole connection cable without feedback
– The feedback signal can be tapped in all proportional modes with 4-wire connection cable
M3P2- and 3-point operationValve path recognition deactivatedThe motor switches off when the valve pressure plate has reached the inner, mechanical stop
M3V2- and 3-point operationValve path recognition
activated
The motor shuts down when the valve pressure plate lifts off the plunger
Caution: Without back pressure from the valve, the valve pressure plate only extends!
By changing the mode, the OEM Motoric Valve Drive 6: 24 V Proportional can also behave like a 2-/3-point actuator:
Updated on May 13, 2024
AppError codes

© 2024 | 300724

  • Supportrequest
  • Privacy Statement
  • Imprint
  • Supportrequest
  • Privacy Statement
  • Imprint