Skip to content
Logo
  • English
    • German

Motoric Valve Drive 24 V (AM3)

  • Disassembly
  • Antitheft device
  • Technical data
  • Diagrams
  • Feedback
  • Function display
  • Initialization
  • Presets
  • Connection
  • Mxx 468×6
  • App
  • Manual setting
  • Notes
  • Montage
  • App
  • App functions
  • Error codes
  • Dimensions

Motoric Valve Drive 6: 24 V proportional failsafe

  • App
  • Disassembly
  • Antitheft device
  • Manual setting
  • App
  • Notes
  • MxxF 468×6
  • Montage
  • Connection
  • Initialization
  • Function display
  • Feedback
  • Diagrams
  • Technical data
  • Antitheft device
  • Dismantling
  • App
  • Error codes
  • Dimensions
  • Presets
  • App functions
  • Failsafe function

Motoric Valve Drive 6: 24 V modbus

  • Function display
  • App
  • Connection
  • Technical data
  • Error codes
  • Diagrams
  • Initialization
  • Presetting
  • App functions
  • MPM 468×6
  • Disassembly
  • Antitheft device
  • Manual setting
  • Dimensions
  • Montage
  • App
  • Notes
  • App

Motoric Valve Drive 6 Downloads

  • Installation instructions
  • Data sheets
  • Motoric Valve Drive 6: 24 V modbus Downloads
  • Motoric Valve Drive 6: 24 V proportional, proportional failsafe Downloads
  • Motoric Valve Drive 6 Downloads
View Categories
  • Systamauswahl
  • Systemauswahl
  • Motoric Valve Drive 6
  • Motoric Valve Drive 6: 24 V modbus
  • App functions

App functions

FUNCTIONDESCRIPTIONDISPLAY
DEVICE OPERATIONS
Read
Read from deviceReading out the settings of the
OEM Motoric Valve Drive: 24 V Modbus RTU
– Ready to scan:
Hold your smartphone near to NFC tag

– Display:
Data was read successfully
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.
Read from filePrerequisite for use:
File stored on the mobile device.

– Reading the settings from a file stored on the mobile device

Ways to store a file on the mobile device:
– Sending files as attachments by message or e-mail
– Storage of file by Write to file command
Display of the file management of the mobile device
Write
Write to deviceSettings are written to the OEM Motoric Valve Drive: 24 V Modbus RTU– Ready to scan:
Hold your smartphone near to NFC tag

– Display:
Data was read successfully
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.
Write to fileScanned settings are stored as a file in the memory of the mobile device.
The file can be used for
– the dispatch by message or mail
– the installation of additional OEM Motoric Valve Drive: 24 V Modbus RTU
Display of the file management of the mobile device
Verify
Verify deviceComparison of the settings displayed in the Settings menu and the settings in the OEM Motoric Valve Drive: 24 V Modbus RTU– Ready to scan:
Hold your smartphone near to NFC tag

– Display:
Data was read successfully
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.

Result:
Validation successful: identical settings
or
Verification failed: different settings
Active operations
Start initializationInitialization of the OEM Motoric Valve Drive: 24 V Modbus RTU

The actuator travels along the actuator path and valve path. The opening and closing points of the valve are stored.
Your device will now begin with the initialization process.
Go to positionSetting the actuator positionSequence:
1. Go to position
2. Confirm
3. Ready to scan:
Hold your smartphone near to the NFC tag.
4. your device will now go to the specified position
or
Error message
→ Repeat the process: The mobile device was moved too early or should be aligned more precisely.
Factory resetAdjusts the parameters of the OEM Motoric Valve Drive: 24 V Modbus RTU to the delivery state.Sequence:
1. Warning message
2. Scan process
Settings
ForceSetting the force in the levels:
100 N, 125 N, 150 N, 200 N
Runtime15 s/mm, 30 s/mm
Valve path recognition (VPR)ON | OFF
Display illuminationON | OFFTurns the LCD backlight on or off.
Drive path2 – 8.5 mmLimitation of the actuator path when the VPR is switched off. Use as a “limiter”.
Bypass0 … 50 %Limitation of the actuator travel in the other direction.

Application: Ensure minimum flow to protect against frost.

Note: Both the rubber diaphragm in the valve and the backlash in the adapter and the gear unit can influence the position. Please check the position!
Valve positionmm | %Sets the preferred display on the LC display.
Baud rate4.800 | 9.600 | 19.200Setting the interface
Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.
ParityNone | Even | OddNone
if necessary, set 2 stop bits at the master

Even
+1 stop bit

Odd
+1 stop bit

Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.
Address1 … 247Setting the Modbus address

Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.

.NOTES.
All modifications must only be carried out with the appropriate expertise. An incorrect setting can lead to malfunctions of the drive, a malfunction of the control system and consequential costs. The manufacturer does not accept any responsibility for incorrect settings and their consequences.
Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.