{"id":5661,"date":"2024-02-27T09:04:06","date_gmt":"2024-02-27T08:04:06","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/app-functions\/"},"modified":"2024-04-15T14:13:08","modified_gmt":"2024-04-15T13:13:08","password":"","slug":"app-functions","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-proportional-failsafe-en\/app-functions\/","title":{"rendered":"App functions"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>FUNCTION<\/strong><\/td><td><strong>DESCRIPTION<\/strong><\/td><td><strong>DISPLAY<\/strong><\/td><\/tr><tr><td>DEVICE OPERATIONS<\/td><td><\/td><td><\/td><\/tr><tr><td><strong>Read<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Read from device<\/td><td>Reading out the settings of the OEM Motoric Valve Drive 6: 24 V Proportional Failsafe<\/td><td>&#8211; Ready to scan:<br\/><strong>Hold your smartphone near to the NFC tag<br\/><\/strong><br\/>&#8211; Display:<br\/><strong>Data was read successfully<\/strong><br\/>or<br\/><strong>Error message<\/strong><br\/>\u2192 Repeat the process: The mobile device has been moved too early or must be aligned more precisely.<\/td><\/tr><tr><td>Read from file<\/td><td><strong>Prerequisite for use:<br\/><\/strong> File stored on the mobile device.<br\/><strong> <\/strong><br\/>&#8211; Reading the settings from a file stored on the mobile device<br\/> <br\/>Ways to store a file on the mobile device:<br\/>&#8211; Sending files as attachments by message or mail<br\/>&#8211; Storage of file by <strong>Write to file<\/strong> command<\/td><td>Display of the file management of the mobile device<\/td><\/tr><tr><td><strong>Write<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Write to device<\/td><td>Settings are written to the OEM Motoric Valve Drive 6: 24 V Proportional Failsafe<\/td><td>&#8211; Ready to scan:<br\/><strong>Hold your smartphone near to NFC tag<br\/><br\/><\/strong> &#8211; Display:<br\/><strong>Data was read successfully<\/strong><br\/>or<br\/><strong>Error message<\/strong><br\/>\u2192 Repeat the process: The mobile device has been moved too early or must be aligned more precisely.<\/td><\/tr><tr><td>Write to file<\/td><td>Scanned settings are stored as a file in the memory of the mobile device.<br\/><br\/>The file can be used for<br\/>&#8211; the dispatch by message or mail<br\/>&#8211; the setup of further OEM Motoric Valve Drive 6: 24 V Proportional Failsafe de-vices<\/td><td>Display of the file management of the mobile device<\/td><\/tr><tr><td><strong>Verify<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Verify device<\/td><td>Comparison of the settings displayed in the Settings menu and the settings in the OEM Motoric Valve Drive 6: 24 V Proportional Failsafe<\/td><td>&#8211; Ready to scan:<br\/><strong>Hold your smartphone near to the NFC tag<br\/><\/strong><br\/>&#8211; Display:<br\/><strong>Data was read successfully<\/strong><br\/>or<br\/><strong>Error message<br\/><\/strong> \u2192 Repeat the process: The mobile device was moved too early or must be aligned more precisely.<br\/><br\/>The result:<br\/><strong>Validation successful<\/strong>: identical settings<br\/>or<br\/><strong>Verification failed<\/strong>: different settings<\/td><\/tr><tr><td><strong>Active operations<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Start initialization<\/td><td>Initialization of the OEM Motoric Valve Drive 6: 24 V Proportional Failsafe<br\/><br\/>The actuator travels along the actuator path and the valve path. The opening and closing points of the valve are stored.<\/td><td><strong>Your device will now begin with the initialization process.<\/strong><\/td><\/tr><tr><td>Go to position<\/td><td>Setting the actuator position<\/td><td>Sequence:<br\/>1. <strong>Go to position<\/strong><br\/>2. <strong>Confirm<\/strong><br\/>3. Ready to scan:<br\/><strong>Hold your smartphone near to the NFC tag.<\/strong><br\/>4. <strong>Your Device will now go to the specified position<\/strong>.<br\/>or<br\/><strong>Error message<\/strong><br\/>\u2192 Repeat the process: The mobile device has been moved too early or must be aligned more precisely.<\/td><\/tr><tr><td>Factory reset<\/td><td>Adjusts the parameters of the OEM Motoric Valve Drive 6: 24 V Proportional Failsafe to the delivery state.<\/td><td>Sequence:<br\/>1. Warning message<br\/>Scan process<\/td><\/tr><tr><td><strong>Settings<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Force<\/td><td>Setting the force in the levels:<br\/>100 N, 125 N, 150 N, 200 N<\/td><td><\/td><\/tr><tr><td>Runtime<\/td><td>15 s\/mm, 30 s\/mm<\/td><td><\/td><\/tr><tr><td>Valve stroke recognition (VSR)<\/td><td>ON | OFF<\/td><td><\/td><\/tr><tr><td>Display illumination<\/td><td>ON | OFF<\/td><td>Turns the LCD backlight on or off.<\/td><\/tr><tr><td>Drive path<\/td><td>2 \u2013 8.5 mm<\/td><td>Limitation of the actuator path when the VPR is switched off. Use as a &#8220;limiter&#8221;.<\/td><\/tr><tr><td>Bypass<\/td><td>0 \u2026 50 %<\/td><td>Limitation of the actuator travel in the other direction.<br\/><br\/><strong>Application:<\/strong> Ensure minimum flow to protect against frost.<br\/><strong>Note: <\/strong>Both the rubber diaphragm in the valve and the backlash in the adapter and the gear unit can influence the posi-tion. Please check the position!<\/td><\/tr><tr><td>Display Valve path<br\/>Valve path display<\/td><td>%<\/td><td>% | mm<\/td><\/tr><tr><td>Failsafe position<\/td><td>0 %<\/td><td>0 \u2026 100 %<br\/>(steps of 10 %)<\/td><\/tr><tr><td>Valve curve<br\/>Valve curve<\/td><td>Linear<\/td><td>Linear | EQP<\/td><\/tr><tr><td>Feedback range<br\/>Functionality<\/td><td>1 \u2013 9 V<\/td><td>1 \u2013 9 V | 1 \u2013 5 V | 0 \u2013 10 V<\/td><\/tr><tr><td>Control voltage \u2013 start<br\/>Control voltage \u2013 Start<\/td><td>0.5 V<\/td><td>0 V \u2026 10 V<br\/>(steps of 0.1 V)<\/td><\/tr><tr><td>Control voltage \u2013 end<br\/>Control voltage \u2013 end<\/td><td>10 V<\/td><td>0 V \u2026 10 V<br\/>(steps of 0.1 V)<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>FUNCTION DESCRIPTION DISPLAY DEVICE OPERATIONS Read Read from device Reading out the settings of the OEM Motoric Valve Drive 6: 24 V Proportional Failsafe &#8211; Ready to scan:Hold your smartphone near to the NFC tag&#8211; Display:Data was read successfullyorError message\u2192 Repeat the process: The mobile device has been moved too early or must be aligned [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[34],"doc_tag":[],"knowledge_base":[33],"class_list":["post-5661","docs","type-docs","status-publish","hentry","doc_category-motoric-valve-drive-6-24-v-proportional-failsafe-en","knowledge_base-motoric-valve-drive-6"],"year_month":"2026-04","word_count":501,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Sandra Palm","author_nicename":"spalm","author_url":"https:\/\/faqdoc.info\/en\/author\/spalm\/"},"doc_category_info":[{"term_name":"Motoric Valve Drive 6: 24 V proportional failsafe","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-proportional-failsafe-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"motoric valve drive 6","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/","term_slug":"motoric-valve-drive-6"}],"knowledge_base_slug":["motoric-valve-drive-6"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=5661"}],"version-history":[{"count":4,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5661\/revisions"}],"predecessor-version":[{"id":6566,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5661\/revisions\/6566"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=5661"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=5661"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=5661"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=5661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}