{"id":5663,"date":"2024-02-27T07:27:05","date_gmt":"2024-02-27T06:27:05","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/default-settings\/"},"modified":"2024-06-04T13:18:35","modified_gmt":"2024-06-04T12:18:35","password":"","slug":"default-settings","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-proportional-failsafe-en\/default-settings\/","title":{"rendered":"Presets"},"content":{"rendered":"\n<p>The OEM Motoric Valve Drive 6: 24 V Proportional Failsafe can be delivered with a custom setting. The properties can be changed subsequently via app. <a href=\"https:\/\/faq.testumgebung.digital\/en\/docs\/motoric-valve-drive-6\/app-functions\/\" data-type=\"link\" data-id=\"https:\/\/faq.testumgebung.digital\/docs\/motoric-valve-drive6\/app-funktionen-2\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">(\u2192 Chapter App functions)<\/mark><\/a><\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Function<\/strong><\/td><td><strong>Default<\/strong><\/td><td><strong>Optional<\/strong><\/td><\/tr><tr><td><strong>Force<\/strong><br\/>Actuation force<\/td><td>125 N<\/td><td>100 N<br\/>125 N<br\/>150 N<br\/>200 N<\/td><\/tr><tr><td><strong>Runtime<\/strong><br\/>Running time<\/td><td>15 s\/mm<\/td><td>15 s\/mm<br\/>30 s\/mm<\/td><\/tr><tr><td><strong>Valve stroke recognition<\/strong><br\/>Valve path recognition<\/td><td>ON<\/td><td>ON<br\/>OFF (OFF= MPRF mode)<\/td><\/tr><tr><td><strong>Display illumination<\/strong><br\/>Display lighting<\/td><td>ON<\/td><td>ON<br\/>OFF<\/td><\/tr><tr><td><strong>Drive path<\/strong><br\/>Stroke<\/td><td>8.5 mm<\/td><td>2 mm &#8230; 8.5 mm<br\/>(steps of 0.1 mm)<\/td><\/tr><tr><td><strong>Valve position<\/strong><br\/>Valve path display<\/td><td>%<\/td><td>%<br\/>mm<\/td><\/tr><tr><td><strong>Failsafe position<\/strong><br\/>only for Failsafe variants<\/td><td>0 %<\/td><td>0 % &#8230; 100 %<\/td><\/tr><tr><td><strong>Valve Curve<\/strong><br\/>Valve curve<\/td><td>Linear<\/td><td>Linear<br\/>EQP<\/td><\/tr><tr><td><strong>Bypass<\/strong><br\/>Minimum valve position<\/td><td>0 %<\/td><td>0 % &#8230; 50 %<br\/>(steps of 1 %)<\/td><\/tr><tr><td><strong>FB Range<\/strong><br\/><strong>(stem dn \u2013 stem up)<\/strong><br\/>Feedback<\/td><td>1 \u2013 9 V<\/td><td>1 \u2013 9 V<br\/>1 \u2013 5 V<br\/>0 \u2013 10 V<\/td><\/tr><tr><td><strong>Control voltage \u2013 start<\/strong><br\/>Control voltage \u2013 start<\/td><td>0.5 V<\/td><td>0 V &#8230; 10 V<br\/>(steps of 0.1 V)<\/td><\/tr><tr><td><strong>Control voltage \u2013 end<\/strong><br\/>Control voltage \u2013 end<\/td><td>10 V<\/td><td>0 V &#8230; 10 V<br\/>(steps of 0.1 V)<\/td><\/tr><tr><td><strong>Actuator Mode<\/strong><\/td><td>MPx<\/td><td>MPx | M3x<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><strong>Example:<\/strong><br\/>Control voltage \u2013 start: 10<br\/>Control voltage \u2013 end: 0 negates the path<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The OEM Motoric Valve Drive 6: 24 V Proportional Failsafe can be delivered with a custom setting. The properties can be changed subsequently via app. (\u2192 Chapter App functions) Function Default Optional ForceActuation force 125 N 100 N125 N150 N200 N RuntimeRunning time 15 s\/mm 15 s\/mm30 s\/mm Valve stroke recognitionValve path recognition ON ONOFF [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[34],"doc_tag":[],"knowledge_base":[33],"class_list":["post-5663","docs","type-docs","status-publish","hentry","doc_category-motoric-valve-drive-6-24-v-proportional-failsafe-en","knowledge_base-motoric-valve-drive-6"],"year_month":"2026-04","word_count":118,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Sandra Palm","author_nicename":"spalm","author_url":"https:\/\/faqdoc.info\/en\/author\/spalm\/"},"doc_category_info":[{"term_name":"Motoric Valve Drive 6: 24 V proportional failsafe","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-proportional-failsafe-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"motoric valve drive 6","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/","term_slug":"motoric-valve-drive-6"}],"knowledge_base_slug":["motoric-valve-drive-6"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5663","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=5663"}],"version-history":[{"count":4,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5663\/revisions"}],"predecessor-version":[{"id":7394,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5663\/revisions\/7394"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=5663"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=5663"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=5663"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=5663"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}