{"id":5721,"date":"2023-11-09T14:54:29","date_gmt":"2023-11-09T13:54:29","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/assembly\/"},"modified":"2024-07-22T08:29:44","modified_gmt":"2024-07-22T07:29:44","password":"","slug":"assembly","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-proportional-failsafe-en\/assembly\/","title":{"rendered":"Connection"},"content":{"rendered":"\n<p><strong>MPRF, MPVF, MPOF<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>24 V a.c. L1 \/ d.c. +<\/td><td>black<\/td><\/tr><tr><td>24 V a.c. L2 \/ d.c. &#8211;<br\/>common ground<\/td><td>blue<\/td><\/tr><tr><td>Control Voltage IN<br\/>0 \u2013 10 V<\/td><td>red<\/td><\/tr><tr><td>Feedback 0 \u2013 10 V<br\/>OUT &lt; 1 mA<\/td><td>yellow<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/faq.testumgebung.digital\/wp-content\/uploads\/2023\/11\/MPxF_468x5_stetig_Verdrahtung_AM3.svg\" alt=\"\" class=\"wp-image-7627\" style=\"width:453px;height:324px\"\/><\/figure>\n\n<p><strong>Connection line<\/strong><br\/>We recommend the following maximum cable lengths for installing a 24 V system:<\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Cable<\/strong><\/td><td><strong>Section<\/strong><\/td><td><strong>Length<\/strong><\/td><\/tr><tr><td>Standard DDC line<\/td><td>0.22 mm\u00b2<\/td><td>20 m<\/td><\/tr><tr><td>J-Y(ST)Y<\/td><td>0.8 mm\u00b2<\/td><td>45 m<\/td><\/tr><tr><td>NYM\/NYIF<\/td><td>1.5 mm\u00b2<\/td><td>136 m<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>Transformer\/power supply unit:<\/strong><br\/>A safety isolating transformer according to EN 61558-2-6 or a switching power supply according to EN 61558-2-16 must always be used. The dimensioning of the transformer or the switching power supply results from the maximum making capacity of the OEM Actuators.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>MPRF, MPVF, MPOF 24 V a.c. L1 \/ d.c. + black 24 V a.c. L2 \/ d.c. &#8211;common ground blue Control Voltage IN0 \u2013 10 V red Feedback 0 \u2013 10 VOUT &lt; 1 mA yellow Connection lineWe recommend the following maximum cable lengths for installing a 24 V system: Cable Section Length Standard DDC [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[34],"doc_tag":[],"knowledge_base":[33],"class_list":["post-5721","docs","type-docs","status-publish","hentry","doc_category-motoric-valve-drive-6-24-v-proportional-failsafe-en","knowledge_base-motoric-valve-drive-6"],"year_month":"2026-04","word_count":96,"total_views":"3","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Cara Z\u00fcchner","author_nicename":"czuechner","author_url":"https:\/\/faqdoc.info\/en\/author\/czuechner\/"},"doc_category_info":[{"term_name":"Motoric Valve Drive 6: 24 V proportional failsafe","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-proportional-failsafe-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"motoric valve drive 6","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/","term_slug":"motoric-valve-drive-6"}],"knowledge_base_slug":["motoric-valve-drive-6"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=5721"}],"version-history":[{"count":4,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5721\/revisions"}],"predecessor-version":[{"id":7839,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/5721\/revisions\/7839"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=5721"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=5721"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=5721"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=5721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}