{"id":6422,"date":"2023-11-06T07:22:35","date_gmt":"2023-11-06T06:22:35","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/electric-connection-2\/"},"modified":"2026-09-14T12:24:54","modified_gmt":"2026-09-14T11:24:54","password":"","slug":"electric-connection-2","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-en\/alpha-direct-balance-switch-switch-modbus-nfc-base-station\/electric-connection-2\/","title":{"rendered":"Electric connection"},"content":{"rendered":"\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2023\/11\/137332_23xx_EA_Warnung.svg\" alt=\"\" class=\"wp-image-589\" style=\"aspect-ratio:1;width:47px;height:auto\"\/><figcaption class=\"wp-element-caption\"><strong>Warning! Electrical voltage! Danger to life! <\/strong><br\/>Before opening, de-energize the base and secure it against being re-energized.<br\/>Disconnect any external voltages connected to the unit and secure it against accidental re-energization.<\/figcaption><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\">For the connection of the power supply, the cable cross-sections must be 0.75 mm\u00b2 \u2013 1.5 mm\u00b2 for 24 V or 1.5 mm\u00b2 for 230 V. Depending on the voltage version of the base, it is possible to take L1 and L2, or L and N, as well as the protective conductor, from the base. A temperature limiter\/dew point sensor can be connected to the TB\/%H contact. If this contact is not used, it must be bridged (provided for at the factory). The bridge must be removed when a connection is established at contact is TB\/%H. The temperature limiter\/dew point sensor must be designed as a normally closed contact.       <br\/>The activation of the special functions as well as the setting of \u201cDisable cooling\u201d and the assignment of the inputs to the outputs can only be set via the app. The external system clock transmits the input signal to the connected thermostats. <\/p>\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2023\/11\/137332_23xx_EA_Elektrischer_Anschluss_2-1.svg\" alt=\"\" class=\"wp-image-596\" style=\"aspect-ratio:1.2684095771735824;width:800px;height:auto\"\/><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\"><strong>The 24 V version of the base station must have a voltage supply via a safety transformer in accordance with EN 61558-2-6 or a Class II transformer in accordance with UL for North America.<\/strong><\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" data-id=\"6180\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2024\/04\/Alpha_Direct_Balance_Switch_front_offen_Anschluesse_24V-3.svg\" alt=\"\" class=\"wp-image-6180\"\/><\/figure>\n<\/figure>\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2023\/11\/137332_23xx_EA_Elektrischer_Anschluss.svg\" alt=\"\" class=\"wp-image-592\" style=\"aspect-ratio:1;width:417px;height:auto\"\/><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>The following parameters can be set via the app: <\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Switch-on delay of the pump<\/td><td>default: 2 minutes<\/td><\/tr><tr><td>Pump follow-up time<\/td><td>default: 2 minutes<\/td><\/tr><tr><td>Switch-on delay of the boiler<\/td><td>default: 0 minutes<\/td><\/tr><tr><td>Nachlaufzeit Boiler<\/td><td>default: 0 minutes<\/td><\/tr><tr><td>Maximum inactive time of the pump before the pump protection function starts <\/td><td>default: 3 days<\/td><\/tr><tr><td>Activation time of the pump (pump protection function) <\/td><td>default: 5 minutes<\/td><\/tr><tr><td>Maximum inactive time of the valve before the valve protection function starts <\/td><td>default: 16 days<\/td><\/tr><tr><td>Valve actuation time (valve protection function)<\/td><td>default: 5 minutes<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2023\/11\/137332_23xx_EA_Information.svg\" alt=\"\" class=\"wp-image-604\" style=\"aspect-ratio:1;width:34px;height:auto\"\/><figcaption class=\"wp-element-caption\">If the base station is configured in a de-energized state, these changes are not applied until the next time power is applied.<\/figcaption><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p class=\"wp-block-paragraph\">A room controller can be assigned to each actuator. Options in the app: <\/p>\n\n<ul class=\"wp-block-list\">\n<li>Adjustment of the listed factory settings<\/li>\n\n\n\n<li>Assignment of names for the corresponding rooms<\/li>\n<\/ul>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Actuators<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Room thermostat<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">1 + 2<\/td><td class=\"has-text-align-center\" data-align=\"center\">1<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">3 + 4<\/td><td class=\"has-text-align-center\" data-align=\"center\">2<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">5 + 6<\/td><td class=\"has-text-align-center\" data-align=\"center\">3<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">7 + 8<\/td><td class=\"has-text-align-center\" data-align=\"center\">4<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">9<\/td><td class=\"has-text-align-center\" data-align=\"center\">5<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">10<\/td><td class=\"has-text-align-center\" data-align=\"center\">6<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">11<\/td><td class=\"has-text-align-center\" data-align=\"center\">7<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">12<\/td><td class=\"has-text-align-center\" data-align=\"center\">8<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>For the connection of the power supply, the cable cross-sections must be 0.75 mm\u00b2 \u2013 1.5 mm\u00b2 for 24 V or 1.5 mm\u00b2 for 230 V. Depending on the voltage version of the base, it is possible to take L1 and L2, or L and N, as well as the protective conductor, from the base. [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"doc_category":[227,228],"doc_tag":[],"knowledge_base":[224,36],"class_list":["post-6422","docs","type-docs","status-publish","hentry","doc_category-alpha-direct-balance-switch-switch-modbus-nfc-base-station","doc_category-alpha-direct-balance-switch-base-station-en","knowledge_base-alpha-direct-en","knowledge_base-alpha-direct-bs-en"],"year_month":"2026-09","word_count":331,"total_views":"5","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Cara Z\u00fcchner","author_nicename":"czuechner","author_url":"https:\/\/faqdoc.info\/en\/author\/czuechner\/"},"doc_category_info":[{"term_name":"Alpha direct Balance Switch \/ Switch Modbus NFC base station","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/non-knowledgebase\/alpha-direct-balance-switch-switch-modbus-nfc-base-station\/"},{"term_name":"Alpha direct Balance Switch base station EN","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-en\/alpha-direct-balance-switch-base-station-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"Alpha direct","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-en\/","term_slug":"alpha-direct-en"},{"term_name":"Alpha direct base station","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-bs-en\/","term_slug":"alpha-direct-bs-en"}],"knowledge_base_slug":["alpha-direct-en","alpha-direct-bs-en"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/6422","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=6422"}],"version-history":[{"count":3,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/6422\/revisions"}],"predecessor-version":[{"id":10382,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/6422\/revisions\/10382"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=6422"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=6422"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=6422"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=6422"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}