{"id":6576,"date":"2023-09-25T09:09:20","date_gmt":"2023-09-25T08:09:20","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/mxxx-468x6-2\/"},"modified":"2025-03-04T14:08:25","modified_gmt":"2025-03-04T13:08:25","password":"","slug":"mxxx-468x6-2","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-24-v-am3-en\/mxxx-468x6-2\/","title":{"rendered":"Mxx 468&#215;6"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2023\/09\/Titel_Motoric_Valve_Drive.svg\" alt=\"\" class=\"wp-image-103\" style=\"aspect-ratio:1;width:167px;height:auto\"\/><\/figure>\n\n<p>MPR 468&#215;6<br\/>MPV 468&#215;6<br\/>MPO 468&#215;6<br\/>M3P 468&#215;6<br\/>M3V 468&#215;6<\/p>\n\n<p>x = (0) 100 N<br\/>x = (2) 125 N<br\/>x = (3) 150 N<br\/>x = (4) 200 N<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p><strong>Variants<\/strong><\/p>\n\n<p>The OEM Motoric Valve Drive 6: 24 V Proportional is supplied in the basic version without logo, with plug-in connection cable and valve adapter. The following versions are available in the basic version: <\/p>\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Type<\/strong><\/td><td><strong>Actuation force<\/strong><\/td><td><strong>Actuation time<\/strong><\/td><td><strong>Control<\/strong><br\/><strong>Voltage range<\/strong><\/td><td><strong>Scope of supply<\/strong><\/td><\/tr><tr><td><strong>MPO 468&#215;6-y0<\/strong><\/td><td>x = 2: 125 N<br\/>x = 0: 100 N<br\/>x = 3: 150 N<br\/>x = 4: 200 N<\/td><td>y = 3: 15 s\/mm<br\/>y = 2: 30 s\/mm<\/td><td>0 \u2013 10 V<br\/><br\/>Active:<br\/>0,5 \u2013 10 V<\/td><td>Motoric Valve Drive: MPx in individual packaging<br\/><br\/>Valve adapter VA80 for all M30x1.5 valves<br\/><br\/>1 m connection line (plug-in), white, PVC 4 x 0.22 mm\u00b2<br\/><br\/>Installation instruction in 12 languages<\/td><\/tr><tr><td><strong>MPV <sup>468&#215;6-y01<\/sup><\/strong><\/td><td>x = 2: 125 N<br\/>x = 0: 100 N<br\/>x = 3: 150 N<br\/>x = 4: 200 N<\/td><td>y = 3: 15 s\/mm<br\/>y = 2: 30 s\/mm<\/td><td>0 \u2013 10 V<br\/><br\/>Active:<br\/>0,5 \u2013 10 V<\/td><td>1 m connection line (plug-in), white, PVC 3 x 0.22 mm\u00b2<\/td><\/tr><tr><td><strong>MPR <sup>468&#215;6-y01<\/sup><\/strong><\/td><td>x = 2: 125 N<br\/>x = 0: 100 N<br\/>x = 3: 150 N<br\/>x = 4: 200 N<\/td><td>y = 3: 15 s\/mm<br\/>y = 2: 30 s\/mm<\/td><td>0 \u2013 10 V<br\/><br\/>Active:<br\/>0,5 \u2013 10 V<\/td><td>1 m connection line (plug-in), white, PVC 3 x 0.22 mm\u00b2<\/td><\/tr><tr><td><strong>M3P 468&#215;6-y0<\/strong><\/td><td>x = 2: 125 N<br\/>x = 0: 100 N<br\/>x = 3: 150 N<br\/>x = 4: 200 N<\/td><td>y = 3: 15 s\/mm<br\/>y = 2: 30 s\/mm<\/td><td>2-\/3-point operation<\/td><td>1 m connection line (plug-in), white, PVC 3 x 0.22 mm\u00b2<\/td><\/tr><tr><td><strong>M3V 468&#215;6-y0<\/strong><\/td><td>x = 2: 125 N<br\/>x = 0: 100 N<br\/>x = 3: 150 N<br\/>x = 4: 200 N<\/td><td>y = 3: 15 s\/mm<br\/>y = 2: 30 s\/mm<\/td><td>2-\/3-point operation, <br\/>with preset valve path recognition<\/td><td>1 m connection line (plug-in), white, PVC 3 x 0.22 mm\u00b2<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Variation options: Preset variants and other valve adaptations on request<br\/><sup>1<\/sup>No feedback due to 3-pole connection cable<\/figcaption><\/figure>\n<\/div>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p><strong>Equipment<\/strong><\/p>\n\n<p>The OEM Motoric Valve Drive 6: 24 V Proportional is supplied fully equipped as standard. The function of the actuator can be changed at the factory or via the APP, so predecessor variants can be simulated. For this purpose, the product comes with a 4-pole cable.  <\/p>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table\"><table><tbody><tr><td><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>MPO 46846<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>MPR 468&#215;6<br\/>Simulation<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>MPV 468&#215;6<br\/>Simulation<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>M3P 468&#215;6<br\/>Simulation<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>M3V<\/strong> <strong>468&#215;6<br\/>Simulation<\/strong><\/td><\/tr><tr><td><strong>LCD<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">Without function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Without function<\/td><\/tr><tr><td><strong>Background illumination<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Switchable<\/td><td class=\"has-text-align-center\" data-align=\"center\">Switchable<\/td><td class=\"has-text-align-center\" data-align=\"center\">Switchable<\/td><td class=\"has-text-align-center\" data-align=\"center\">Without function<\/td><td class=\"has-text-align-center\" data-align=\"center\">Without function<\/td><\/tr><tr><td><strong>Function display via LED<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><\/tr><tr><td><strong>Valve path recognition<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">X<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">X<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><\/tr><tr><td><strong>Feedback signal<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td><strong>Manual setting<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><\/tr><tr><td><strong>4-pole connection cable<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><td class=\"has-text-align-center\" data-align=\"center\"><\/td><\/tr><tr><td><strong>3-pole connection cable,<br\/>minimum version<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Not available<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<br\/>Feedback not usable<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<br\/>Feedback not usable<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u221a<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p><strong>Valve adaptation<\/strong><\/p>\n\n<p>The OEM Motoric Valve Drive 6: 24 V Proportional is supplied with a VA80 valve adapter ring as standard. The actuator can also be connected to other valves without any problems. The adapters cover a valve path of 8 mm each, measured from the minimum closed component.  <\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Valve adapters<\/strong><\/td><td><strong>Minimum locking dimension with<br\/>OEM Motoric Valve Drive 6: 24 V Proportional<\/strong><\/td><td><strong>Valve manufacturer<\/strong><\/td><\/tr><tr><td><strong>VA 80 \u2013 M30 x 1.5 mm<\/strong><\/td><td>8.5 mm<\/td><td>Danfoss ABQM<br\/>Flowcon<br\/>Frese<br\/>Herz<br\/>Honeywell<br\/>IVAR<br\/>JCI<br\/>Oventrop<br\/>Sauter<br\/>Siemens<br\/>TA<br\/>Watts<\/td><\/tr><tr><td><strong>VA 33 \u2013 M28 x <strong>1.5 mm<\/strong><\/strong><\/td><td>8 mm<\/td><td>Herz<br\/>JCI<\/td><\/tr><tr><td><strong>VA 64 \u2013 M28 x <strong>1.5 mm<\/strong><\/strong><\/td><td>15.8 mm<\/td><td>Pettinaroli<\/td><\/tr><tr><td><strong>VA 67 \u2013 M30 x <strong>1.5 mm<\/strong><\/strong><\/td><td>11 mm<\/td><td>Controlli<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>MPR 468&#215;6MPV 468&#215;6MPO 468&#215;6M3P 468&#215;6M3V 468&#215;6 x = (0) 100 Nx = (2) 125 Nx = (3) 150 Nx = (4) 200 N Variants The OEM Motoric Valve Drive 6: 24 V Proportional is supplied in the basic version without logo, with plug-in connection cable and valve adapter. The following versions are available in the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[25],"doc_tag":[],"knowledge_base":[33],"class_list":["post-6576","docs","type-docs","status-publish","hentry","doc_category-motoric-valve-drive-24-v-am3-en","knowledge_base-motoric-valve-drive-6"],"year_month":"2026-04","word_count":370,"total_views":"8","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"admin","author_nicename":"faq-admin","author_url":"https:\/\/faqdoc.info\/en\/author\/faq-admin\/"},"doc_category_info":[{"term_name":"Motoric Valve Drive 24 V (AM3)","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-24-v-am3-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"motoric valve drive 6","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/","term_slug":"motoric-valve-drive-6"}],"knowledge_base_slug":["motoric-valve-drive-6"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/6576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=6576"}],"version-history":[{"count":6,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/6576\/revisions"}],"predecessor-version":[{"id":8844,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/6576\/revisions\/8844"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=6576"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=6576"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=6576"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=6576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}