{"id":7042,"date":"2023-09-26T07:54:53","date_gmt":"2023-09-26T06:54:53","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/connection\/"},"modified":"2024-07-22T08:46:19","modified_gmt":"2024-07-22T07:46:19","password":"","slug":"connection","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-24-v-am3-en\/connection\/","title":{"rendered":"Connection"},"content":{"rendered":"\n<p><strong>MPR, MPV, MPO<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>24 V a.c. L1 \/ d.c. +<\/td><td>black<\/td><\/tr><tr><td>24 V a.c. L2 \/ d.c. \u2013 common ground<\/td><td>blue<\/td><\/tr><tr><td>Control Voltage, IN 0 \u2013 10 V<\/td><td>red<\/td><\/tr><tr><td>Feedback 0 \u2013 10 V, OUT &lt; 1 mA<\/td><td>yellow<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/faq.testumgebung.digital\/wp-content\/uploads\/2024\/07\/MPx_468x5_stetig_Verdrahtung_AM3.svg\" alt=\"\" class=\"wp-image-7604\" style=\"width:453px;height:324px\"\/><\/figure>\n\n<p><strong>Connection line<\/strong><br\/>We recommend the following maximum cable lengths for installing a 24 V system:<\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Cable<\/strong><\/td><td><strong>Section<\/strong><\/td><td><strong>Length<\/strong><\/td><\/tr><tr><td>Standard DDC line<\/td><td>0.22 mm\u00b2<\/td><td>20 m<\/td><\/tr><tr><td>J-Y(ST)Y<\/td><td>0.8 mm\u00b2<\/td><td>45 m<\/td><\/tr><tr><td>NYM\/NYIF<\/td><td>1.5 mm\u00b2<\/td><td>136 m<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong>Transformer\/power supply unit<\/strong><br\/>A safety isolating transformer according to EN 61558-2-6 or a switching power supply according to EN 61558-2-16 must always be used.<br\/>The dimensioning of the transformer or the switching power supply results from the maximum making capacity of the OEM Actuators.<\/p>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p>M3P\/M3V: <strong>3-point control<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Feature<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>L2 common ground (blue)<\/td><td>Ground<\/td><\/tr><tr><td>L1-2 (voltage to red)<\/td><td>Valve pressure plate retracts<\/td><\/tr><tr><td>L1-1 (voltage to black)<\/td><td>Valve pressure plate extracts<\/td><\/tr><tr><td>No voltage to red\/black<\/td><td>Valve pressure plate remains in the current position<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/faq.testumgebung.digital\/wp-content\/uploads\/2023\/09\/M3F_468x5_3_Punkt_Verdrahtung_2241.svg\" alt=\"\" class=\"wp-image-4763\" style=\"width:434px;height:auto\"\/><\/figure>\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n<p>M3P\/M3V: <strong>2-point control<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Feature<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>L2 common ground (blue)<\/td><td>Ground<\/td><\/tr><tr><td>L1-2 (voltage to red)<\/td><td>Valve pressure plate retracts<\/td><\/tr><tr><td>L1-1 (voltage to black)<\/td><td>Valve pressure plate extracts<\/td><\/tr><tr><td>No voltage to red\/black<\/td><td>Valve pressure plate remains in the current position<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/faq.testumgebung.digital\/wp-content\/uploads\/2024\/07\/Verdrahtung_M3P.svg\" alt=\"\" class=\"wp-image-7649\" style=\"width:450px;height:auto\"\/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>MPR, MPV, MPO 24 V a.c. L1 \/ d.c. + black 24 V a.c. L2 \/ d.c. \u2013 common ground blue Control Voltage, IN 0 \u2013 10 V red Feedback 0 \u2013 10 V, OUT &lt; 1 mA yellow Connection lineWe recommend the following maximum cable lengths for installing a 24 V system: Cable Section [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[25],"doc_tag":[],"knowledge_base":[33],"class_list":["post-7042","docs","type-docs","status-publish","hentry","doc_category-motoric-valve-drive-24-v-am3-en","knowledge_base-motoric-valve-drive-6"],"year_month":"2026-04","word_count":172,"total_views":"4","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Sandra Palm","author_nicename":"spalm","author_url":"https:\/\/faqdoc.info\/en\/author\/spalm\/"},"doc_category_info":[{"term_name":"Motoric Valve Drive 24 V (AM3)","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-24-v-am3-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"motoric valve drive 6","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/","term_slug":"motoric-valve-drive-6"}],"knowledge_base_slug":["motoric-valve-drive-6"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/7042","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=7042"}],"version-history":[{"count":3,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/7042\/revisions"}],"predecessor-version":[{"id":7854,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/7042\/revisions\/7854"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=7042"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=7042"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=7042"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=7042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}