{"id":7156,"date":"2024-05-13T13:09:40","date_gmt":"2024-05-13T12:09:40","guid":{"rendered":"https:\/\/faq.testumgebung.digital\/docs\/non-knowledgebase\/app-functions-3\/"},"modified":"2024-05-13T13:51:49","modified_gmt":"2024-05-13T12:51:49","password":"","slug":"app-functions-3","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-modbus-en\/app-functions-3\/","title":{"rendered":"App functions"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>FUNCTION<\/strong><\/td><td><strong>DESCRIPTION<\/strong><\/td><td><strong>DISPLAY<\/strong><\/td><\/tr><tr><td>DEVICE OPERATIONS<\/td><td><\/td><td><\/td><\/tr><tr><td><strong>Read<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Read from device<\/td><td>Reading out the settings of the <br\/>OEM Motoric Valve Drive: 24 V Modbus RTU<\/td><td>\u2013 Ready to scan:<br\/><strong>Hold your smartphone near to NFC tag<br\/><br\/><\/strong> \u2013 Display:<br\/><strong>Data was read successfully<\/strong><br\/>or<br\/><strong>Error message<\/strong><br\/>\u2192 Repeat the process: The mobile device was moved too early or should be aligned more precisely.<\/td><\/tr><tr><td>Read from file<\/td><td><strong>Prerequisite for use:<br\/><\/strong> File stored on the mobile device.<br\/><strong> <\/strong><br\/>\u2013 Reading the settings from a file stored on the mobile device<br\/> <br\/>Ways to store a file on the mobile device:<br\/>\u2013 Sending files as attachments by message or e-mail<br\/>\u2013 Storage of file by <strong>Write to file<\/strong> command<\/td><td>Display of the file management of the mobile device<\/td><\/tr><tr><td><strong>Write<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Write to device<\/td><td>Settings are written to the OEM Motoric Valve Drive: 24 V Modbus RTU<\/td><td>\u2013 Ready to scan:<br\/><strong>Hold your smartphone near to NFC tag<br\/><br\/><\/strong> \u2013 Display:<br\/><strong>Data was read successfully<\/strong><br\/>or<br\/><strong>Error message<\/strong><br\/>\u2192 Repeat the process: The mobile device was moved too early or should be aligned more precisely.<\/td><\/tr><tr><td>Write to file<\/td><td>Scanned settings are stored as a file in the memory of the mobile device.<br\/>The file can be used for<br\/>\u2013 the dispatch by message or mail<br\/>\u2013 the installation of additional OEM Motoric Valve Drive: 24 V Modbus RTU<\/td><td>Display of the file management of the mobile device<\/td><\/tr><tr><td><strong>Verify<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Verify device<\/td><td>Comparison of the settings displayed in the <strong>Settings <\/strong>menu and the settings in the OEM Motoric Valve Drive: 24 V Modbus RTU<\/td><td>\u2013 Ready to scan:<br\/><strong>Hold your smartphone near to NFC tag<br\/><br\/><\/strong> \u2013 Display:<br\/><strong>Data was read successfully<\/strong><br\/>or<br\/><strong>Error message<br\/><\/strong> \u2192 Repeat the process: The mobile device was moved too early or should be aligned more precisely.<br\/><br\/>Result:<br\/><strong>Validation successful<\/strong>: identical settings<br\/>or<br\/><strong>Verification failed<\/strong>: different settings<\/td><\/tr><tr><td><strong>Active operations<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Start initialization<\/td><td>Initialization of the OEM Motoric Valve Drive: 24 V Modbus RTU<br\/><br\/>The actuator travels along the actuator path and valve path. The opening and closing points of the valve are stored.<\/td><td><strong>Your device will now begin with the initialization process.<\/strong><\/td><\/tr><tr><td>Go to position<\/td><td>Setting the actuator position<\/td><td>Sequence:<br\/>1. <strong>Go to position<\/strong><br\/>2. <strong>Confirm<\/strong><br\/>3. Ready to scan:<br\/><strong>Hold your smartphone near to the NFC tag.<\/strong><br\/>4. <strong>your device will now go to the specified position<\/strong><br\/>or<br\/><strong>Error message<\/strong><br\/>\u2192 Repeat the process: The mobile device was moved too early or should be aligned more precisely.<\/td><\/tr><tr><td>Factory reset<\/td><td>Adjusts the parameters of the OEM Motoric Valve Drive: 24 V Modbus RTU to the delivery state.<\/td><td>Sequence:<br\/>1. Warning message<br\/>2. Scan process<\/td><\/tr><tr><td><strong>Settings<\/strong><\/td><td><\/td><td><\/td><\/tr><tr><td>Force<\/td><td>Setting the force in the levels:<br\/>100 N, 125 N, 150 N, 200 N<\/td><td><\/td><\/tr><tr><td>Runtime<\/td><td>15 s\/mm, 30 s\/mm<\/td><td><\/td><\/tr><tr><td>Valve path recognition (VPR)<\/td><td>ON | OFF<\/td><td><\/td><\/tr><tr><td>Display illumination<\/td><td>ON | OFF<\/td><td>Turns the LCD backlight on or off.<\/td><\/tr><tr><td>Drive path<\/td><td>2 \u2013 8.5 mm<\/td><td>Limitation of the actuator path when the VPR is switched off. Use as a &#8220;limiter&#8221;.<\/td><\/tr><tr><td>Bypass<\/td><td>0 &#8230; 50 %<\/td><td>Limitation of the actuator travel in the other direction.<br\/><br\/><strong>Application:<\/strong> Ensure minimum flow to protect against frost.<br\/> <br\/><strong>Note:<\/strong> Both the rubber diaphragm in the valve and the backlash in the adapter and the gear unit can influence the position. Please check the position!<\/td><\/tr><tr><td>Valve position<\/td><td>mm | %<\/td><td>Sets the preferred display on the LC display.<\/td><\/tr><tr><td>Baud rate<\/td><td>4.800 | 9.600 | 19.200<\/td><td>Setting the interface<br\/>Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.<\/td><\/tr><tr><td>Parity<\/td><td>None | Even | Odd<\/td><td><strong>None<\/strong><br\/>if necessary, set 2 stop bits at the master<br\/><br\/><strong>Even<\/strong><br\/>+1 stop bit<br\/><br\/><strong>Odd<\/strong><br\/>+1 stop bit<br\/><br\/>Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.<\/td><\/tr><tr><td>Address<\/td><td>1 &#8230; 247<\/td><td>Setting the Modbus address<br\/><br\/>Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p><strong><mark style=\"background-color:#abb8c3\" class=\"has-inline-color has-cyan-bluish-gray-color\">.<\/mark><\/strong><mark style=\"background-color:#abb8c3\" class=\"has-inline-color has-white-color\"><strong>NOTES<\/strong><\/mark><strong><mark style=\"background-color:#abb8c3\" class=\"has-inline-color has-cyan-bluish-gray-color\">.<\/mark><\/strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-cyan-bluish-gray-color\"><br\/><\/mark>All modifications must only be carried out with the appropriate expertise. An incorrect setting can lead to malfunctions of the drive, a malfunction of the control system and consequential costs. The manufacturer does not accept any responsibility for incorrect settings and their consequences.<br\/>Adoption of changes after restarting the OEM Motoric Valve Drive: 24 V Modbus RTU.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>FUNCTION DESCRIPTION DISPLAY DEVICE OPERATIONS Read Read from device Reading out the settings of the OEM Motoric Valve Drive: 24 V Modbus RTU \u2013 Ready to scan:Hold your smartphone near to NFC tag \u2013 Display:Data was read successfullyorError message\u2192 Repeat the process: The mobile device was moved too early or should be aligned more precisely. [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[32],"doc_tag":[],"knowledge_base":[33],"class_list":["post-7156","docs","type-docs","status-publish","hentry","doc_category-motoric-valve-drive-6-24-v-modbus-en","knowledge_base-motoric-valve-drive-6"],"year_month":"2026-04","word_count":578,"total_views":"3","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Sandra Palm","author_nicename":"spalm","author_url":"https:\/\/faqdoc.info\/en\/author\/spalm\/"},"doc_category_info":[{"term_name":"Motoric Valve Drive 6: 24 V modbus","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/motoric-valve-drive-6-24-v-modbus-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"motoric valve drive 6","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/motoric-valve-drive-6\/","term_slug":"motoric-valve-drive-6"}],"knowledge_base_slug":["motoric-valve-drive-6"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/7156","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=7156"}],"version-history":[{"count":4,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/7156\/revisions"}],"predecessor-version":[{"id":7168,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/7156\/revisions\/7168"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=7156"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=7156"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=7156"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=7156"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}