{"id":8746,"date":"2025-01-31T08:42:11","date_gmt":"2025-01-31T07:42:11","guid":{"rendered":"https:\/\/faqdoc.info\/?post_type=docs&#038;p=8746"},"modified":"2025-08-15T09:58:20","modified_gmt":"2025-08-15T08:58:20","password":"","slug":"register-description","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-balance-switch-en\/alpha-direct-balance-switch-nfc-base-station-en\/register-description\/","title":{"rendered":"Register description"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Register<\/strong><\/td><td><strong>Address<\/strong><\/td><td><strong>Command<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>0 \u2013 7<\/td><td>0x0000<br\/>\u2013<br\/>0x0007<\/td><td>R<\/td><td>Serial number (UID): The UID is a unique number that can be used to identify the device.<br\/>(8 decimal values, 1 value per register)<\/td><\/tr><tr><td>8 \u2013 15<\/td><td>0x0008<br\/>\u2013<br\/>0x000F<\/td><td>R<\/td><td>Device type in plain text: ADBS230M, ADBS24 M<br\/>(8 characters, 1 character per register)<\/td><\/tr><tr><td>16<\/td><td>0x0010<\/td><td>R<\/td><td>Major software version as decimal value<\/td><\/tr><tr><td>17<\/td><td>0x0011<\/td><td>R<\/td><td>Minor software version as decimal value<\/td><\/tr><tr><td>18<\/td><td>0x0012<\/td><td>R<\/td><td>reserved<\/td><\/tr><tr><td>19<\/td><td>0x0013<\/td><td>R \/ W<\/td><td><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Changeover: Control via Modbus<\/mark><\/strong><br\/><br\/><strong>Bit 0 = 0<\/strong>: Control changeover via external input<br\/><strong>Bit 0 = 1<\/strong>: Control changeover via Modbus<br\/><strong>Bit 1 = 0<\/strong>: Control changeover via Modbus inactive (Heating mode)<br\/><strong>Bit 1 = 1<\/strong>: Control changeover via Modbus active (Cooling mode)<br\/><strong>Bit 2 to bit 15<\/strong>: reserved<\/td><\/tr><tr><td>20 \u2013 31<\/td><td>0x0014<br\/>\u2013<br\/>0x001F<\/td><td>R \/ W<\/td><td>Assignment of an input (room) to an output (for each output a register starting with 0x0014 for output 1)<br\/><br\/>0 = No room assigned<br\/><br\/>1 \u2013 8 = Room number<br\/>(default = 1, 1, 2, 2, 3, 3, 4, 4, 5, 6, 7, 8)<br\/><br\/>Persistent storage possible via initialisation command<\/td><\/tr><tr><td>32 \u2013 43<\/td><td>0x0020<br\/>\u2013<br\/>0x002B<\/td><td>R<\/td><td>Info for initial state PWM (one register per output, starting with 0x0020 for output 1)<br\/><br\/>Unit: %<br\/>Value range: 0 \u2013 100 Resolution: 1<br\/><br\/>Without load sharing:<br\/>Activation actuator = 100<br\/>No actuation of actuator = 0<br\/><br\/>PWM accuracy: \u00b12 %<br\/><br\/>Operating mode queried via register 0x002E<\/td><\/tr><tr><td>44<\/td><td>0x002C<\/td><td>W<\/td><td><strong>Trigger commands:<\/strong><br\/>0 = No Command<br\/>1 = Factory reset<br\/>2 = Initialisation<br\/>3 = FirstOpen function<br\/>4 = ManualOpen function (with parameter, see register 0x002D)<br\/>5 = Normal mode<br\/>6 = Input Simulation (see register 0x0034 \u2026 0x003B)<\/td><\/tr><tr><td>45<\/td><td>0x002D<\/td><td>R \/ W<\/td><td>Parameters for command in register 0x002C<br\/><br\/>Use for command ManualOpen: Bit mask for outputs to be activated, e.g. 0x00F0<\/td><\/tr><tr><td>46<\/td><td>0x002E<\/td><td>R<\/td><td><strong>Active Mode<\/strong><br\/>0 = Normal<br\/>1 = FirstOpen<br\/>2 = ManualOpen<br\/>3 = Input Simulation<\/td><\/tr><tr><td>47<\/td><td>0x002F<\/td><td>R \/ W<\/td><td><strong>Modbus address<\/strong><br\/>1 \u2013 247<br\/>(default: 1)<br\/><br\/>Persistent storage possible via command for initialisation<\/td><\/tr><tr><td>48<\/td><td>0x0030<\/td><td>R \/ W<\/td><td><strong>Baud rate<\/strong><br\/>0 = 4.800<br\/>1 = 9.600<br\/>2 = 19.200<br\/>3 = 38.400 (default)<br\/><br\/>Persistent storage possible via command for initialisation<\/td><\/tr><tr><td>49<\/td><td>0x0031<\/td><td>R \/ W<\/td><td><strong>Parity<\/strong><br\/>0 = none*<br\/>1 = even (default)<br\/>2 = odd<br\/><br\/>*2 stop bits automatically<br\/><br\/>Persistent storage possible via command for initialisation<\/td><\/tr><tr><td>50<\/td><td>0x0032<\/td><td>R<\/td><td><strong>Information on whether outputs are participating in load balancing<\/strong><br\/>Bit 0: Output 1<br\/>Bit 1: Output 2<br\/>\u2026<br\/>Bit 11: Output 12<br\/><br\/>Bit = 0 \u2192 load balancing inactive<br\/>Bit = 1 \u2192 load balancing active<\/td><\/tr><tr><td>51<\/td><td>0x0033<\/td><td>R<\/td><td><strong>Info on whether inputs are participating in load balancing<\/strong><br\/>Bit 0: Input 1<br\/>Bit 1: Input 2<br\/>\u2026<br\/>Bit 7: Input 8<br\/><br\/>Bit = 0 \u2192 load balancing inactive<br\/>Bit = 1 \u2192 load balancing active<\/td><\/tr><tr><td>52 \u2013 59<\/td><td>0x0034<br\/>\u2013<br\/>0x003B<\/td><td>R \/ W<\/td><td><strong>Simulated PWM for the inputs<\/strong><br\/>(a register for each input, starting with 0x0034 for input 1)<br\/><br\/>Unit: %<br\/>Range of values: 0 \u2013 100 Resolution: 1<br\/><br\/>Evaluation of the 8 registers in Input Simulation mode<br\/><br\/>Default: Pulse-pause ratio at the inputs<br\/><br\/>No participation in load balancing when:<br\/>&#8211; PWM = 0 %<br\/>&#8211; PWM = 100 %<br\/><br\/>When participating in load balancing, the input LED lights up if at least one heating zone assigned to the room is active. <br\/><br\/>In cooling mode, the outputs are controlled according to the load balancing.<\/td><\/tr><tr><td>60<\/td><td>0x003C<\/td><td>R<\/td><td>reserved<\/td><\/tr><tr><td>61<\/td><td>0x003D<\/td><td>R<\/td><td><strong>Heating\/cooling mode<\/strong><br\/>0 = heating<br\/>1 = cooling<\/td><\/tr><tr><td>62<\/td><td>0x003E<\/td><td>R<\/td><td><strong>Status of pump<\/strong><br\/>0 = pump off<br\/>1 = pump on<\/td><\/tr><tr><td>63<\/td><td>0x003F<\/td><td>R<\/td><td><strong>Status of boiler<\/strong><br\/>0 = boiler off<br\/>1 = boiler on<\/td><\/tr><tr><td>64<\/td><td>0x0040<\/td><td>R<\/td><td><strong>Mode Commissioning<\/strong><br\/>0 = Commissioning inactive<br\/>1 = Commissioning active<\/td><\/tr><tr><td>65<\/td><td>0x0041<\/td><td>R<\/td><td><strong>Status of dew point sensor<\/strong><br\/>0 = Condensation detected<br\/>1 = Monitoring the dew point is active<\/td><\/tr><tr><td>66<\/td><td>0x0042<\/td><td>R<\/td><td><strong>Status reduction<\/strong><br\/>0 = reduction inactive<br\/>1 = reduction active<\/td><\/tr><tr><td>67<\/td><td>0x0043<\/td><td>R \/ W<\/td><td><strong>Block cooling<\/strong><br\/>Flag for each output<br\/>Bit 0: Output 1<br\/>Bit 1: Output 2<br\/>\u2026<br\/>Bit 11: Output 12<br\/><br\/>Persistent storage possible via initialisation command<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">R: Read, W: Write<\/figcaption><\/figure>\n\n<ul class=\"wp-block-list\">\n<li>Register consisting of 16 bits<\/li>\n\n\n\n<li>Data types:<br\/>&#8211; decimal<br\/>&#8211; bit masks<br\/>&#8211; explicitly stated otherwise (e.g. device type in plain text)<\/li>\n\n\n\n<li>Storing changes to persistent parameters AFTER the initialisation command<\/li>\n<\/ul>\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Register Address Command Description 0 \u2013 7 0x0000\u20130x0007 R Serial number (UID): The UID is a unique number that can be used to identify the device.(8 decimal values, 1 value per register) 8 \u2013 15 0x0008\u20130x000F R Device type in plain text: ADBS230M, ADBS24 M(8 characters, 1 character per register) 16 0x0010 R Major software [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[133],"doc_tag":[],"knowledge_base":[36],"class_list":["post-8746","docs","type-docs","status-publish","hentry","doc_category-alpha-direct-balance-switch-nfc-base-station-en","knowledge_base-alpha-direct-balance-switch-en"],"year_month":"2026-04","word_count":484,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Sandra Palm","author_nicename":"spalm","author_url":"https:\/\/faqdoc.info\/en\/author\/spalm\/"},"doc_category_info":[{"term_name":"Alpha direct Balance Switch NFC base station","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-balance-switch-en\/alpha-direct-balance-switch-nfc-base-station-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"Alpha direct Balance Switch","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-balance-switch-en\/","term_slug":"alpha-direct-balance-switch-en"}],"knowledge_base_slug":["alpha-direct-balance-switch-en"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/8746","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=8746"}],"version-history":[{"count":4,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/8746\/revisions"}],"predecessor-version":[{"id":9085,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/8746\/revisions\/9085"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=8746"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=8746"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=8746"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=8746"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}