{"id":9079,"date":"2023-11-03T12:12:00","date_gmt":"2023-11-03T11:12:00","guid":{"rendered":"https:\/\/faqdoc.info\/systemauswahl\/non-knowledgebase\/uncategorized\/device-overview-2\/"},"modified":"2025-08-15T08:57:44","modified_gmt":"2025-08-15T07:57:44","password":"","slug":"device-overview-2","status":"publish","type":"docs","link":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-balance-switch-en\/alpha-direct-balance-switch-nfc-base-station-en\/device-overview-2\/","title":{"rendered":"Device overview"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Connections and indications <\/h3>\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" data-id=\"6076\" src=\"https:\/\/faqdoc.info\/wp-content\/uploads\/2024\/04\/137332_2247_EA_AdBB_Bx1902-08N2-01.svg\" alt=\"\" class=\"wp-image-6076\"\/><\/figure>\n<\/figure>\n\n<p>1 &#8211; Boiler connection<br\/> 2 &#8211; Pump connection<br\/> 3 &#8211; Protective earth connection (230 V only)<br\/> 4 &#8211; Voltage supply<br\/> 5 &#8211; Fuse<br\/> 6 &#8211; Temperature limiter or dew point monitor<br\/> 7 &#8211; Changeover heating\/cooling<br\/> 8 &#8211; Setback temperature channel external timer<br\/> 9 &#8211; Thermostat connection<br\/> 10 &#8211; LED<br\/> 11 &#8211; NFC antenna<br\/> 12 &#8211; Connection of valve drives<br\/> 13 &#8211; Strain relief<\/p>\n\n<h3 class=\"wp-block-heading\">Technical data <\/h3>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Operating voltage<\/td><td>24 V \u00b120 %, 50 Hz,<br\/>230 V \u00b110 %, 50 Hz<\/td><\/tr><tr><td>Power consumption<\/td><td>max. 50 VA<\/td><\/tr><tr><td>Power consumption (idle)<\/td><td>&lt;1 W<\/td><\/tr><tr><td>Fuse<\/td><td>24 V: T2A<br\/>230 V: T4AH<\/td><\/tr><tr><td>Connectable room controllers<\/td><td>max. 8<\/td><\/tr><tr><td>Connectable room controllers<\/td><td>A 20&#215;05, AST 20&#215;05, A 40&#215;05, AST 40&#215;05<\/td><\/tr><tr><td>Connectable valve drives<\/td><td>max. 12 actuators<\/td><\/tr><tr><td>Inrush current per valve drive<\/td><td>230 V: max. 500 mA<\/td><\/tr><tr><td>max. permissible nominal load of the connectable valve drives<\/td><td>24 V: max. 24 W<\/td><\/tr><tr><td><strong>Pump connection Switching capacity<\/strong><\/td><td>2 A, 200 VA induktiv<\/td><\/tr><tr><td>&#8211; Turn-on delay<\/td><td>parametrisable (default: 2 minutes)<\/td><\/tr><tr><td>&#8211; Follow-up time<\/td><td>parametrisable (default: 2 minutes)<\/td><\/tr><tr><td><strong>Boiler connection Switching capacity<\/strong><\/td><td>2 A, 200 VA induktiv<\/td><\/tr><tr><td>&#8211; Turn-on delay<\/td><td>parametrisable (default: 0 parametrisable )<\/td><\/tr><tr><td>&#8211; Follow-up time<\/td><td>parametrisable (default: 0 parametrisable )<\/td><\/tr><tr><td>Pump protection<\/td><td>parametrisable (default: 3 days \/ 5 min.)<\/td><\/tr><tr><td>Valve protection<\/td><td>parametrisable (default: 3 days \/ 5 min.)<\/td><\/tr><tr><td>Valve drive operating principle<\/td><td>NC<\/td><\/tr><tr><td>Ambient temperature<\/td><td>0 \u2026 50 \u00b0C<\/td><\/tr><tr><td>Storage temperature \/ transport temperature<\/td><td>-20 \u2026 +70 \u00b0C<\/td><\/tr><tr><td>Ambient humidity<\/td><td>5-80 %, non-condensing<\/td><\/tr><tr><td>ERP class according to EU 811\/2013<\/td><td>1=1 %<\/td><\/tr><tr><td>Contamination degree<\/td><td>2<\/td><\/tr><tr><td>Rated impulse voltage<\/td><td>1500 V<\/td><\/tr><tr><td>Protection class<\/td><td>24 V: III<br\/>230V: II<\/td><\/tr><tr><td>Protection type:<\/td><td>IP20<\/td><\/tr><tr><td>Function<\/td><td>Type 1 \/ type 1.C<\/td><\/tr><tr><td>Dimensions (H x W x D)<\/td><td>90 x 326,5 x 52 mm<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n<h3 class=\"wp-block-heading\">Display<\/h3>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>LED heating zones<\/td><td>green (one LED per HZ)<\/td><\/tr><tr><td>LED fuse<\/td><td>red<\/td><\/tr><tr><td>LED power<\/td><td>green \/ red (two-coloured)<\/td><\/tr><tr><td>LED pump<\/td><td>green<\/td><\/tr><tr><td>LED boiler<\/td><td>green<\/td><\/tr><tr><td>LED heating \/ cooling<\/td><td>green<\/td><\/tr><tr><td>LED Modbus<\/td><td>Flashing orange for Modbus activity<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Connections and indications 1 &#8211; Boiler connection 2 &#8211; Pump connection 3 &#8211; Protective earth connection (230 V only) 4 &#8211; Voltage supply 5 &#8211; Fuse 6 &#8211; Temperature limiter or dew point monitor 7 &#8211; Changeover heating\/cooling 8 &#8211; Setback temperature channel external timer 9 &#8211; Thermostat connection 10 &#8211; LED 11 &#8211; NFC [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"doc_category":[133],"doc_tag":[],"knowledge_base":[36],"class_list":["post-9079","docs","type-docs","status-publish","hentry","doc_category-alpha-direct-balance-switch-nfc-base-station-en","knowledge_base-alpha-direct-balance-switch-en"],"year_month":"2026-04","word_count":212,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"Cara Z\u00fcchner","author_nicename":"czuechner","author_url":"https:\/\/faqdoc.info\/en\/author\/czuechner\/"},"doc_category_info":[{"term_name":"Alpha direct Balance Switch NFC base station","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-balance-switch-en\/alpha-direct-balance-switch-nfc-base-station-en\/"}],"doc_tag_info":[],"knowledge_base_info":[{"term_name":"Alpha direct Balance Switch","term_url":"https:\/\/faqdoc.info\/en\/systemauswahl\/alpha-direct-balance-switch-en\/","term_slug":"alpha-direct-balance-switch-en"}],"knowledge_base_slug":["alpha-direct-balance-switch-en"],"_links":{"self":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/9079","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/comments?post=9079"}],"version-history":[{"count":1,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/9079\/revisions"}],"predecessor-version":[{"id":9081,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/docs\/9079\/revisions\/9081"}],"wp:attachment":[{"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/media?parent=9079"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_category?post=9079"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/doc_tag?post=9079"},{"taxonomy":"knowledge_base","embeddable":true,"href":"https:\/\/faqdoc.info\/en\/wp-json\/wp\/v2\/knowledge_base?post=9079"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}