Device overview

Alpha direct Balance base station  ·  https://faqdoc.info/en/systemauswahl/alpha-direct-en/alpha-direct-balance-base-station/device-overview/

Connections and displays 230 V

1 - Boiler connection
2 - Pump connection
3 - Protective conductor connection (only for 230 V)
4 - Voltage supply
5 - Fuse
6 - Temperature limiter or dew point sensor
7 - Heating/cooling change-over
8 - Reduction channel, external timer
9 - Thermostat connection
10 - LED
11 - DIP switch "disable cooling"
12 - Connection of actuators
13 - Strain relief

Technical data

Operating voltage:24 V ±20 %, 50 Hz,
230 V ±10 %, 50 Hz
Power consumption:max. 50 VA
Power consumption (idle):<1 W
Fuse:24 V: T2A / 230 V: T4AH
Connectable room thermostats:max. 8
Connectable actuators, type:A 20x05, AST 20x05, A 40x05, AST 40x05
Connectable actuators:max. 17 actuators
The following applies to other actuators than those mentioned above
Inrush current per actuator:230 V: max. 500 mA
max. permitted nominal load
of the connectable actuators:
24 V: max. 24 W
Pump control switching power:2 A, 200 VA induktiv
Switch-on delay:2 minutes
Follow-up time:2 minutes
Boiler control switching power:2 A, 200 VA induktiv
Switch-on delay:2 minutes
Follow-up time:2 minutes
Pump protection function:3 days / 5 min.
Valve protection function:16 days / 5 min.
Control direction of actuators:NC
Ambient temperature:0 to 50 °C
Storage temperature:-20 to 70 °C
Ambient humidity:80 %, non-condensing
ERP class acc. to EU 811/2013:1=1 %
Contamination degree:2
Rated surge voltage:1500 V
Protection class:24 V: III / 230V: II
Protection type:IP 20
Function:Type 1 / type 1.C
Dimensions (H x L x D):90 x 326,5 x 52 mm