Alpha direct Balance base station

  • Intended use
  • Device overview
  • Montage
  • Electric connection
  • LED signaling
  • Commissioning mode
  • Automated hydraulic balancing
  • Maintenance
  • Disassembly
  • Hydraulic balancing remains necessary
  • Automatic heat distribution
  • Flow limiter not required
  • Cross-distribution network balancing required
  • Base station learning phase
  • Calibration
  • Compatibility
  • Cooling application
  • Switching between heating and cooling
  • Boiler control system
  • Bypassing heating zones
  • Valve protection

Alpha direct downloads

  • Alpha direct Balance Downloads
  • Alpha direct Balance Switch / Balance Switch Modbus downloads
  • TÜV certificates
  • Alpha direct Thermostat 55 Matrix downloads

Balance NFC app

  • Requirements for using NFC
  • Privacy policy
  • App functions
  • Download the app

Alpha direct thermostat 55 Matrix

  • Connection diagram / port overview
  • Function »Heating– Cooling«
  • Setting the corresponding parameters
  • Setting the target temperature
  • Operating lock
  • Set display to standby mode
  • Switching the device on / off
  • RMO (operating mode)
  • BOS (Boost)
  • PRG (heating program)
  • Setting up heating programs
  • VAT (Temperature holiday mode)
  • BRW / BRS (Display brightness)
  • NET (Set up WiFi)
  • DAT (date, time)
  • SWT (summer time / winter time)
  • INS (Installer)
  • CMO (control algorithm)
  • WEH (type of heating)
  • SMO (sensor mode)
  • DIF (Hysteresis)
  • ADP (Smart Start)
  • FLT (Temperature limiter floor sensor)
  • VAL (operating principle)
  • VPA / VPD (Valve protection)
  • TSS (temperature unit)
  • WMO (manual heating / cooling)
  • CAR / CAF / CAE (calibration)
  • ALO / AHI (setpoint limiter)
  • FLO / FHI (setpoint limiter)
  • ELO / EHI (setpoint limiter)
  • ANT (time automatically)
  • COL (block cooling)
  • FAC (factory reset)
  • ESC (exit)
  • Alpha smart app

Automated hydraulic balancing

  • How it works
  • A practical guide for technicians: Hydraulic balancing using automated systems
  • Applying for government grants
  • TÜV certificates

Alpha direct Balance Switch base station

  • Intended use
  • Device overview
  • Montage
  • Electric connection
  • LED signaling
  • Commissioning mode
  • Automated hydraulic balancing
  • Maintenance
  • Disassembly
  • Balance NFC app
  • Hydraulic balancing remains necessary
  • Automatic heat distribution
  • Flow limiter not required
  • Cross-distribution network balancing required
  • Base station learning phase
  • Calibration
  • Compatibility
  • Cooling application
  • Switching between heating and cooling
  • Boiler control system
  • Bypassing heating zones
  • Valve protection

Alpha direct Balance Switch Modbus base station

  • Intended use
  • Device overview
  • Montage
  • Electric connection
  • LED signaling
  • Commissioning mode
  • Automated hydraulic balancing
  • Register description
  • Maintenance
  • Disassembly
  • Balance NFC app
  • Hydraulic balancing remains necessary
  • Automatic heat distribution
  • Flow limiter not required
  • Cross-distribution network balancing required
  • Base station learning phase
  • Calibration
  • Compatibility
  • Cooling application
  • Switching between heating and cooling
  • Boiler control system
  • Bypassing heating zones
  • Valve protection
View Categories
  • Systemauswahl
  • Alpha direct
  • Alpha direct Balance base station
  • Hydraulic balancing remains necessary

Hydraulic balancing remains necessary

Does the Alpha direct Balance base station replace conventional hydraulic balancing in accordance with Method B?

The Alpha direct Balance base station features an integrated control system for automated hydraulic balancing, which was recertified by TÜV Rheinland in 2026. The product can be used to carry out hydraulic balancing in accordance with Method B, as set out in the ZVSHK/VdZ/VDMA technical regulation.

The Alpha direct Balance base station falls into the category of temperature-based methods. The system operates on the basis of temperature-dependent load balancing across the heating circuits, rather than on the calculation or setting of target flow rates in accordance with hydraulic balancing in accordance with Method B. Its use therefore does not exempt the user from complying with the basic requirements for hydraulic balancing in accordance with Method B. In particular, the base station can only influence the system components from the heating manifold onwards. Sections of the pipework network and components upstream of the heating manifold or the heat transfer unit are not taken into account by the control algorithm.

As described in section 8.03 of the BEG EM Minimum Technical Requirements, temperature-based methods only come into effect from the heating manifold onwards. As hydraulic balancing in accordance with Method B takes the entire heating system into account, all system components upstream of the heat exchanger must also meet the requirements for hydraulic balancing in accordance with Method B.

The use of the Alpha direct Balance base station therefore does not fully replace all the requirements for hydraulic balancing in accordance with Method B. The specifications set out in the relevant VdZ forms and technical regulations must still be observed. You can find detailed information on automated hydraulic balancing and government funding schemes in the chapter: Automatisierter hydraulischer Abgleich

Note on eligibility – as at August 2026 #

Carrying out a hydraulic balancing using a temperature-based method for the Alpha direct Balance base station is eligible for BEG funding.

Customers are currently eligible for BEG funding towards the purchase price of the products and for carrying out hydraulic balancing using alternative temperature-based methods, provided they complete Procedure B in full. Our products have been recertified by TÜV Rheinland on the basis of the new requirements set out by the Federal Ministry for Economic Affairs and Climate Action (BMWK) and the German Federal Office for Economic Affairs and Export Control (BAFA), and their jointly published checklist.

The BAFA (the German Federal Office for Economic Affairs and Export Control) & BMWK checklist aims to provide clarity regarding the requirements that alternative hydraulic balancing methods under Method B must meet in order to be recognised as equivalent under the Federal Funding Scheme for Efficient Buildings (BEG).

Updated on September 30, 2026
DisassemblyAutomatic heat distribution